International Journal of Obstetric Anesthesia
Volume 15, Issue 3 , Pages 201-205, July 2006

A randomised double-blinded controlled trial of the effect of diluent volume on the efficacy of a single dose of epidural ropivacaine for labour analgesia

  • L. Chan
  • ,
  • B.B. Lee
  • ,
  • W.D. Ngan Kee

      Affiliations

    • Corresponding Author InformationCorrespondence to: W.D. Ngan Kee, Department of Anaesthesia and Intensive Care, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong, China. Tel.: +852 2632 2735; fax: +852 2637 2422.

Department of Anaesthesia and Intensive Care, The Chinese University of Hong Kong, Hong Kong, China

Accepted 1 November 2005.

Lina Chan MBBS, FHKAM, Bee B. Lee MBBS, FANZCA, FHKAM, Warwick D. Ngan Kee MBChB, MD, FANZCA, FHKAM, Department of Anaesthesia and Intensive Care, The Chinese University of Hong Kong, Hong Kong, China.

Background

Few studies have systematically investigated the effect of diluent volume on the efficacy of epidural local anaesthetics for labour analgesia and no data are available for ropivacaine. Our aim was to compare epidural ropivacaine given in three different volumes for labour analgesia.

Methods

In a double-blinded study, we randomly assigned 60 labouring parturients with cervical dilatation <5 cm to receive epidural ropivacaine 30 mg diluted to 5 mL (group 5, n=20), 10 mL (group 10, n=20) or 20 mL (group 20, n=20) for analgesia. We measured visual analogue scale pain scores at the peak of contraction for 30 min plus onset and duration of analgesia.

Results

Pain scores at 30 min were similar among group 5 (median 22 [interquartile range 0-44] mm), group 10 (9 [0-21] mm) and group 20 (37 [0-51] mm), P=0.35. The number of patients who achieved a decrease in pain score to ⩽30% of baseline was similar among group 5 (12/20 (60%)), group 10 (17/20 (85%)) and group 20 (11/19 (58%)), P=0.13. Onset and duration of analgesia, the incidence of motor block and patient satisfaction were similar among groups.

Conclusions

Under the conditions of this study, within the range of 5-20 mL, the volume and concentration were not significant factors influencing the efficacy of a single 30-mg bolus of epidural ropivacaine given for labour analgesia. This suggests that the most important factor influencing analgesic efficacy was drug mass.

Keywords: Epidural analgesia, Labour, Local anaesthetics, Ropivacaine

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0959-289X(05)00183-4

doi:10.1016/j.ijoa.2005.11.001

International Journal of Obstetric Anesthesia
Volume 15, Issue 3 , Pages 201-205, July 2006