International Journal of Obstetric Anesthesia
Volume 18, Issue 4 , Pages 342-345, October 2009

A United Kingdom national obstetric intubation equipment survey

  • A.S. Bullough

      Affiliations

    • Corresponding Author InformationCorrespondence to: Dr Alexandra S. Bullough, Department of Anesthesiology, University of Michigan, 1500 East Medical Center Drive, Ann Arbor, Michigan 48105, USA. Tel.: +1 734 936 4280; fax: +1 734 936 90 91.
  • ,
  • M. Carraretto

Department of Anaesthesia, Great Western Hospitals NHS Foundation Trust, Swindon Wiltshire, UK

Accepted 15 January 2009. published online 22 July 2009.

Abstract 

Background

Failed intubation is relatively common in the obstetric patient. Overall, there has been a decline in experience of general anaesthesia in obstetrics. The level of anaesthetic preparedness in the event of a difficult obstetric intubation is unknown.

Methods

With approval from the Obstetric Anaesthetists’ Association, a national postal survey of obstetric units in the United Kingdom was conducted. The survey addressed airway equipment availability and existence of difficult airway algorithms and formal difficult airway drills. The number of deliveries, general anaesthetic cases and failed intubations in each unit was also ascertained.

Results

One hundred and eighty-seven units completed the national obstetric intubation equipment survey questionnaire (78% response rate). All obstetric units possessed a laryngoscope with a normal handle and adult Macintosh blade, a bougie and a laryngeal mask airway. A 7.0 internal diameter endotracheal tube was most often used for securing the airway, and 90% of units stored all airway equipment on a designated difficult airway trolley. A fiberoptic bronchoscope was not readily available and on average it would take >10min to obtain. A failed intubation incidence of 1:309 was reported. Only one third of units promoted difficult airway training.

Conclusion

Essential airway equipment was readily available in the event of a difficult obstetric intubation, with the exception of a fiberoptic bronchoscope. Few units conduct difficult airway training.

Keywords: Obstetric airway equipment, Difficult airway training

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0959-289X(09)00048-X

doi:10.1016/j.ijoa.2009.01.015

International Journal of Obstetric Anesthesia
Volume 18, Issue 4 , Pages 342-345, October 2009